产品详情
主营产品简介
专注于DCS、PLC、机器人控制系统、大型伺服四大系统领域。
主营产品各种模块/卡件,控制器,触摸屏,伺服驱动器。
优势:供应进口原装正品,专业停产配件,
发货快,货期精准,
主营品牌包括 ABB贝利、GE/FUANC、FOXBORO、英维思TRICONEX 、本特利BENTLY、A-B罗克韦尔、艾默生EMERSON 、OVATION、MOTOROLA、XYVOM、霍尼韦尔HONEYWELL 、力士乐REXROTH、KUKA、NI、DEIF、横河、伍德沃德WOODWARD、瑞恩、施耐德SCHNEIDER 、安川、 穆格MOOG、PROSOFT等品牌
产品图片展示

产品详情资料
况下,该配置将一个处理器分配给处理器机箱的左侧插槽。System Configurator允许选择端口、IRIG和系统功能选项。PD-T8082中描述了System Configurator的使用。选项描述如下。3.1.1.更新程序部分如果选择了自动保护网络变量,这会将受信任系统配置为使用简化的Modbus协议映射。有关更多详细信息,请参阅产品说明PD-8151B(可信通信接口模块)。组间延迟等同于Modbus更新周期。这是发送到每个通信接口模块的连续Modbus更新消息之间的短时间。默认值(如图所示)为50毫秒,这在延迟和性能之间提供了折衷。调整以32整数毫秒为增量进行,即33的值等于64毫秒,64的值也等于64毫秒。这可以根据需要增加或减少,但是,由于每个应用程序扫描只发送一条更新消息,并且应用程序扫描通常可能超过50毫秒,因此调整此变量没有什么好处。3.1.2.安全部分上述显示还用于配置密码,允许用户使用基于Windows的超级终端设备或类似终端程序查询受信任系统。通过选择新密码按钮并在显示的对话框中输入两次新密码来配置密码。3.1.3.ICS2000节本节仅适用于通过可信ICS2000接口适配器连接到ICS2000系统的可信系统。这允许选择三个模拟表的数据源。有关更多信息,请咨询您的受信任供应商。The Trusted TMR Processor requires no hardware configuration. Every Trusted System requires a System.INI configuration file. Details of how to design this are given in PD-T8082 (Trusted Toolset Suite). The configuration has a Processor assigned to the left slot of the Processor chassis by default. The System Configurator allows the selection of options on ports, IRIG and system functions. The use of the System Configurator is described in PD-T8082. The options are described below. 3.1.1. Updater Section If Auto Protect Network Variables is selected, this configures the Trusted System to use a reduced Modbus Protocol map. See product description PD-8151B (Trusted Communication Interface Module) for further details. Inter Group Delay equates to the Modbus update cycle. This is the minimum period between successive Modbus update messages sent to each of the Communications Interface Modules. The default value (as shown) is 50 ms which provides a compromise between latency and performance. Adjustment is made in 32 integer ms increments, i.e. a value of 33 will equal 64 ms as will 64.This may be increased or decreased as required, however since only one update message is sent per application scan, and an application scan may often be more than 50 ms, there is little benefit in adjusting this variable. 3.1.2. Security Section The above display is also used to configure a password allowing the user to interrogate a Trusted System using the Windows-based HyperTerminal facility or a similar terminal program. The password is configured by selecting the New Password button and entering the new password twice in the displayed dialogu